Behavior of Particulate Matter Immission (PM10, PM2.5, Ultrafine Particles) at the Paiba station, of the Air Quality Surveillance System, of the Francisco José de Caldas District University
| dc.creator | Murad Pedraza, José Alejandro | |
| dc.creator | Martin Rivera, Jason Stevens | |
| dc.creator | García Leal, Stephany Alexandra | |
| dc.date | 2024-10-29 | |
| dc.date.accessioned | 2025-12-19T17:27:57Z | |
| dc.date.available | 2025-12-19T17:27:57Z | |
| dc.description | Particulate matter (PM) is a major sources of air pollution, p osing significant health risks, particularly to vulnerable populations. This study examines the behavior of pm concentrations (PM 10, PM2.5, and ultrafine particles) at the Paiba station, part of the Air Quality Monitoring System (SVCA) at Universidad Distrital Francisco José de Caldas. Meteorological data and pm concentration levels were collected and analyzed. Linear and stationary pollution sources in the area of influence were identifiedand characterized. A spatiotemporal analysis of PM behavior was also conducted. The findings indicate that furnaces and boilers are the most significant stationary sources of pollution in the area, with natural gas being the predominant fuel. Additionally, the arterial road network represents the main source of linear pollution. While only a weak association was found between PM concentrations and meteorological variables, a statistically significant correlation was observed between PM10 and PM2.5 levels. | en-US |
| dc.description | El material particulado (MP) es una de las principales fuentes de contaminación del aire, lo que supone un riesgo significativo para la salud de las poblaciones vulnerables. El presente estudio analiza el comportamiento de concentraciones de MP (menor a 10, 2 ,5 micras y partículas ultrafinas [UF]) en la estación de la sede Paiba, del Sistema de Vigilancia de la Calidad del Aire (SVCA), de la Universidad Distrital Francisco José de Caldas. Se realizaron los procedimientos necesarios para obtener información meteorológica y de concentración de MP, se caracterizaron fuentes lineales y fijas en el área de influencia, y se realizó un análisis espacio temporal del comportamiento del MP. En la zona analizada, los hornos y calderas son las fuentes que más contaminan, y la mayoría de las fuentes de combustión utilizan gas como combustible. La malla vial arterial es la principal fuente de contaminación lineal. Además, se encontró una asociación débil entre las concentraciones de MP y las variables meteorológicas, pero se detectó una correlación estadísticamente significativa entre el MP10 y el MP2,5. | es-ES |
| dc.description | O material particulado (MP) é uma das principais fontes de poluição do ar, representando um risco significativo para a saúde de populações vulneráveis. O presente estudo analisa o comportamento das concentrações de MP (menor que 10, 2,5 micrômetros e p artículas ultrafinas [UF]) na estação da sede Paiba, do Sistema de Vigilância da Qualidade do Ar (SVCA), da Universidade Distrital Francisco José de Caldas. Foram realizados os procedimentos necessários para obter informaçõesmeteorológicas e de concentração de MP, caracterizaram-se fontes lineares e fixas na área de influência, e foi realizada uma análise espaço-temporal do comportamento do MP. Na área analisada, os fornos e caldeiras são as principais fontes de poluição, e a maioria das fontes de combustão utiliza gás como combustível. A malha viária arterial é a principal fonte de poluição linear. Além disso, foi encontrada uma pequena associação entre as concentrações de MP e as variáveis meteorológicas, mas detectou-se uma correlação estatisticamente significativa entre o MP10 e o MP2,5 | pt-BR |
| dc.format | application/pdf | |
| dc.format | text/xml | |
| dc.identifier | https://revistas.umng.edu.co/index.php/rcin/article/view/7488 | |
| dc.identifier | 10.18359/rcin.7488 | |
| dc.identifier.uri | https://dspace7.infotegra.com/dspace7demo/45349 | |
| dc.language | spa | |
| dc.publisher | Universidad Militar Nueva Granada | es-ES |
| dc.relation | https://revistas.umng.edu.co/index.php/rcin/article/view/7488/6153 | |
| dc.relation | https://revistas.umng.edu.co/index.php/rcin/article/view/7488/6410 | |
| dc.relation | /*ref*/A. S. López, Procesos irritativos relacionados con la contaminación ambiental en la ciudad de Esmeraldas, Tesis PG, Pontificia Universidad Católica del Ecuador, sede Esmeraldas, 40 p., 2022. | |
| dc.relation | /*ref*/Y. Guerra y V. Torres, “Contaminantes atmosféricos y su incidencia sobre la reproducción en murinos y humanos”, Actualidades Biológicas, vol. 45, no. 118, pp. 1-13, 2023, https://doi.org/10.17533/udea.acbi/v45n118a02 | |
| dc.relation | /*ref*/US EPA. (2023). Efectos del material particulado (mp) sobre la salud y el medio ambiente. [En línea]. Disponible en: https://espanol.epa.gov/espanol/efectos-del-material-particulado-pm-sobre-la-salud-y-el-medioambiente | |
| dc.relation | /*ref*/J. Araujo y A. Nel, “Particulate matter and atherosclerosis: Role of particle size, composition and oxidative stress”, Particle and fibre toxicology, vol. 6, no. 24, 2009. Disponible en https://pubmed.ncbi.nlm.nih.gov/19761620/ | |
| dc.relation | /*ref*/US EPA. (2023). Contaminación por partículas (mp). [En línea]. Disponible en: https://www.epa.gov/MP-pollution/particulate-matter-MP-basics | |
| dc.relation | /*ref*/B. Artíñano, P. Salvador, D. Alonso, X. Querol y A. Alastuey, “Anthropogenic and natural influence on the MP 10 and MP2.5 aerosol in Madrid (Spain). Analysis of high concentration episodes”, Environmental Pollution, vol. 125, no. 3, pp. 453-465, 2003, https://doi.org/10.1016/S0269-7491(03)00078-2 | |
| dc.relation | /*ref*/P. Baltrënas y J. Morkûnienë, “Investigación de la concentración de partículas en el aire del distrito de Žvërynas en Vilna”, Revista de Ingeniería Ambiental y Gestión del Paisaje, vol. 14, no. 1. pp. 23-30, 2006, https://doi.org/10.3846/16486897.2006.9636875 | |
| dc.relation | /*ref*/J. Richmond, C. Saganich, L. Bukiewicz, R. Kalin, “Associations of mp2.5 and black carbon concentrations with traffic, idling, background pollution, and meteorology during school dismissals”, Science of The Total Environment, vol.407, no. 10. pp. 3357-3364, https://doi.org/10.1016/j.scitotenv.2009.01.046 | |
| dc.relation | /*ref*/J. Sternbeck, Å. Sjödin y K. Andréasson, “Metal emissions from road traffic and the influence of resuspension-results from two tunnel studies”, Atmospheric Environment, vol. 36, no. 30, pp. 4735-4744, 2002, https://doi.org/10.1016/S1352-2310(02)00561-7 | |
| dc.relation | /*ref*/C. A. Arciniegas, “Diagnóstico y control de material particulado: partículas suspendidas totales y fracción respirable MP10”, Luna Azul, vol. 8, no. 34. pp. 195-213, 2012. Disponible en: https://www.redalyc.org/pdf/3217/321727348012.pdf | |
| dc.relation | /*ref*/I. Toro, J. Ramírez, R. Quiceno y C. Zuluaga, “Cálculo de la emisión vehicular de contaminantes atmosféricos en la ciudad de Medellín mediante factores de emisión corinair”, Acodal, no. 191. pp.42-49, 2001. Disponible en: https://es.slideshare.net/slideshow/vehiculos1/19645690 | |
| dc.relation | /*ref*/A. J. Arrieta, “Dispersión de material particulado (mp10), con Interrelación de factores meteorológicos y topográficos”, Revista Ingeniería Investigación y Desarrollo, vol. 16, no. 2, pp. 43-54, 2016, Disponible en : https://revistas.uptc.edu.co/index.php/ingenieria_sogamoso/article/view/5445/4515 | |
| dc.relation | /*ref*/Ministerio de Ambiente y Desarrollo Sostenible. (2017). “Guía para la elaboración de inventarios de emisiones atmosféricas”. [En línea]. Disponible en: https://www.minambiente.gov.co/wp-content/uploads/2022/03/GUIA_PARA_LA_ELABORACION_DE_INVENTARIOS_DE_EMISIONES_ATMOSFERICAS.pdf | |
| dc.relation | /*ref*/Universidad Eafit. (2018). “Análisis estadístico de las fracciones de material particulado y sus diferentes métodos de medición en el Valle de Aburrá”, Informe especial, Análisis material particulado, Contrato Ciencia y Tecnología 511 de 2017. [En línea]. Disponible en: https://www.metropol.gov.co/ambiental/calidad-del-aire/Biblioteca-aire/Estudios-calidad-del-aire/Analisis-MP10-MP25.pdf | |
| dc.relation | /*ref*/Ministerio de Ambiente y Desarrollo Sostenible. (2017). “Resolución 2254 del 2017”. [En línea]. Disponible en: https://www.alcaldiabogota.gov.co/sisjur/normas/Norma1.jsp?i=82634 | |
| dc.rights | Derechos de autor 2024 Ciencia e Ingeniería Neogranadina | es-ES |
| dc.rights | https://creativecommons.org/licenses/by-nc-nd/4.0 | es-ES |
| dc.source | Ciencia e Ingenieria Neogranadina; Vol. 34 No. 2 (2024); 111 - 129 | en-US |
| dc.source | Ciencia e Ingeniería Neogranadina; Vol. 34 Núm. 2 (2024); 111 - 129 | es-ES |
| dc.source | Ciencia e Ingeniería Neogranadina; v. 34 n. 2 (2024); 111 - 129 | pt-BR |
| dc.source | 1909-7735 | |
| dc.source | 0124-8170 | |
| dc.subject | contaminación atmosférica | es-ES |
| dc.subject | aire | es-ES |
| dc.subject | estadística | es-ES |
| dc.subject | correlación | es-ES |
| dc.subject | industria | es-ES |
| dc.subject | combustión | es-ES |
| dc.subject | combustible | es-ES |
| dc.subject | vehículo | es-ES |
| dc.subject | poluição atmosférica | pt-BR |
| dc.subject | ar | pt-BR |
| dc.subject | estatística | pt-BR |
| dc.subject | correlação | pt-BR |
| dc.subject | indústria | pt-BR |
| dc.subject | combustão | pt-BR |
| dc.subject | combustível | pt-BR |
| dc.subject | veículo | pt-BR |
| dc.subject | Atmospheric Pollution | en-US |
| dc.subject | Air | en-US |
| dc.subject | Statistics | en-US |
| dc.subject | Correlation | en-US |
| dc.subject | Industry | en-US |
| dc.subject | Combustion | en-US |
| dc.subject | Fuel | en-US |
| dc.subject | Vehicle | en-US |
| dc.title | Behavior of Particulate Matter Immission (PM10, PM2.5, Ultrafine Particles) at the Paiba station, of the Air Quality Surveillance System, of the Francisco José de Caldas District University | en-US |
| dc.title | Comportamiento de la inmisión en cuanto a material particulado (MP10 -MP2,5 - Partículas UF) en la estación Paiba, del Sistema de Vigilancia de Calidad del Aire, de la Universidad Distrital Francisco José de Caldas | es-ES |
| dc.title | Comportamento da imissão em termos de material particulado (MP10 - MP2.5 - UF Partículas) na estação Paiba, do Sistema de Vigilância da Qualidade do Ar, da Universidade Distrital Francisco José de Caldas | pt-BR |
| dc.type | info:eu-repo/semantics/article | |
| dc.type | info:eu-repo/semantics/publishedVersion |